Abstract

Design of pyramidal blackbody source in the desired frequency range of 60-90 GHz, using the CST Microwave studio is presented. Silicon Carbide (SiC) blackbody source is being developed for the radiometric calibration at Institute of Plasma Research. Parametric study of pyramidal blackbody source is accomplished by changing the various dimensions of the structure. The final design of the structure and its characteristic performance, deduced from the simulations, in the desired frequency band has been described.

Keywords

Blackbody, Calibration, CST Microwave Studio, Radiometer.

References

[1] H. Nornikman, P.J Soh, A.A.H. Azermi, H.M.R Nurul, “Parametric Study of Pyramidal Microwave Absorber design,” School of computer and communication engineering, University of Malaysia Perlis.
[2] H. Nornikman, P.J Soh, A.A.H. Azermi, H.M.R Nurul, “Reflection Loss Performance of Triangular Microwave Absorber,” School of computer and communication engineering, University of Malaysia Perlis..
[3] David K Cheng, “Field and Wave Electromagnetics”, second edition, Addison Wesley, 1989.pp411-417”.
[4] Bekefi, G and Barrett, A.H,“Electromagnetics Vibrations, Waves and Radiation”, Cambridge, MA: MIT Press, NEC2 Modeling of Fractal Element Antennae (FEA), pp 418-420
[5] B.K. Chung, H.T. chuah, “Modelling of RF Absorber for Application in The Design of Anechoic Chamber”, Electromagnetic Research, PIER42, 2003, pp 273-285.
[6] K.Kawahata, M.Sakamoto, J.Fujita, H.Matsuo and K.Sakai, “Calibration Source for Electron Cyclotron Emission Measurements”, Japan .Journal. Applied Physics 29 (1990) pp 1824-1828.
[7] R.H.Dicke “Measurement of Thermal Radiation at Microwave Frequencies”, Revised Scientific Instrument .17, 268 (1946).
[8] F. C. Smith, B. Chambers, J. C. Bennett, “Calibration measurements”, IEEE Proceedings-A, Vol.139, No5, 247-253, Sep, 1992.

Time: 0.0013 sec Memory: 32 KB
Current: 1.88 MB
Peak: 4 MB